From: Factors causing peak energy consumption of reefers at container terminals
Model 6 | R | R2 | Adjusted R2 | Std. Error of the Estimate |
---|---|---|---|---|
.911 | .830 | .827 | 12,333 | |
Unstandardized Coefficients | Standardized Coefficients | |||
β | Std. error | β | t-value | |
(Constant) | 41,088.919 | 30.417 | Â | 1.35 |
No_arr_reefers | 174.390 | 5.7 | .850*** | 30.43 |
avg_dwelltime | 6,855.187 | 959 | .198*** | 7.15 |
avg_specif_heat | −22,775.935 | 8475 | −.81** | −2.69 |
avg_thermal_iso | 15,218.523 | 7423 | .062* | 2.08 |
deltaT_plugin | 14,190.340 | 6503 | .061* | 2.18 |